SAFETY MODEL NO. | PP60A05 | PP60A07 | PP60A09 | PP60A12 | |
DC VOLTAGE | 5V | 7.5V | 9V | 12V | |
RATED CURRENT | 6A | 6A | 6A | 5A | |
CURRENT RANGE | 0 ~ 6A | 0 ~ 6A | 0 ~ 6A | 0 ~ 5A | |
RATED POWER | 30W | 45W | 54W | 60W | |
RIPPLE & NOISE | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | |
VOLTAGE TOLERANCE | ±5.0% | ±5.0% | ±5.0% | ±3.0% | |
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LOAD REGULATION | ±5.0% | ±5.0% | ±5.0% | ±3.0% | |
SETUP, RISE TIME | 1000ms, 50ms / 230VAC 1000ms, 50ms / 115VAC at full load | ||||
HOLD UP TIME | 50ms / 230VAC 15ms / 115VAC at full load | ||||
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | |||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
EFFICIENCY | 85.5% | 88.5% | 89% | 89.5% | |
AC CURRENT | 1.4A / 115VAC 1A / 230VAC | ||||
INRUSH CURRENT | 65A / 230VAC | ||||
LEAKAGE CURRENT | 0.75mA / 240VAC | ||||
PROTECTION | OVERLOAD | 105 ~ 150% rated output power | |||
Protection type: Hiccup mode, recovers automatically after the fault condition is removed | |||||
OVERVOLTAGE | 5.25 ~ 6.75V | 7.88 ~ 10.13V | 9.45 ~ 12.15V | 12.6 ~ 16.2V | |
Protection type: Shut down o/p voltage, re-power on to recover | |||||
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover | ||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70°C(Refer to "Derating Curve") | |||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40 ~ +85°C , 10 ~ 95% RH | ||||
TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 50°C) | ||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||
SAFETY & EMC | SAFETY STANDARDS | U60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1,AS/NZS 60950.1 approved | |||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC / 25°C/ 70% RH | ||||
EMC EMISSION | Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CAN ICES-3(B)/NMB-3(B),CNS13438 class B, GB9254, GB17625.1 | ||||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A | ||||
MTBF | 709.7K hrs min. MIL-HDBK-217F (25°C ) | ||||
DIMENSION | 125*50*31.5mm (L*W*H) | ||||
PACKING | 0.305Kg; 40pcs/13.02Kg/1.05CUFT |
SAFETY MODEL NO. | GST60A15 | GST60A18 | GST60A24 | GST60A48 | |
DC VOLTAGE | 15V | 18V | 24V | 48V | |
RATED CURRENT | 4A | 3.33A | 2.5A | 1.25A | |
CURRENT RANGE | 0 ~ 4A | 0 ~ 3.33A | 0 ~ 2.5A | 0 ~ 1.25A | |
RATED POWER | 60W | 60W | 60W | 60W | |
RIPPLE & NOISE | 150mVp-p | 150mVp-p | 180mVp-p | 240mVp-p | |
VOLTAGE TOLERANCE | ±3.0% | ±3.0% | ±3.0% | ±2.5% | |
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LOAD REGULATION | ±3.0% | ±3.0% | ±3.0% | ±2.5% | |
SETUP, RISE TIME | 1000ms, 50ms / 230VAC 1000ms, 50ms / 115VAC at full load | ||||
HOLD UP TIME | 50ms / 230VAC 15ms / 115VAC at full load | ||||
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | |||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
EFFICIENCY | 89.5% | 89.5% | 90.5% | 92% | |
AC CURRENT | 1.4A / 115VAC 1A / 230VAC | ||||
INRUSH CURRENT | 65A / 230VAC | ||||
LEAKAGE CURRENT | 0.75mA / 240VAC | ||||
PROTECTION | OVERLOAD | 105 ~ 150% rated output power | |||
Protection type: Hiccup mode, recovers automatical ly after fault condition is removed | |||||
OVER VOLTAGE | 15.75 ~ 20.25V | 18.9 ~ 24.3V | 25.2 ~ 32.4V | 50.4 ~ 64.8V | |
Protection type : Shut down o/p voltage, re-power on to recover | |||||
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover | ||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70°C(Refer to "Derating Curve") | |||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40 ~ +85°C , 10 ~ 95% RH | ||||
TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 50°C) | ||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||
SAFETY & EMC | SAFETY STANDARDS | U60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1,AS/NZS 60950.1 approved | |||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC / 25°C/ 70% RH | ||||
EMC EMISSION | Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CAN ICES-3(B)/NMB-3(B),CNS13438 class B, GB9254, GB17625.1 | ||||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A | ||||
MTBF | 709.7K hrs min. MIL-HDBK-217F (25°C ) | ||||
DIMENSION | 125*50*31.5mm (L*W*H) | ||||
PACKING | 0.305Kg; 40pcs/13.02Kg/1.05CUFT |